Monday, 1 December 2014
Toyota Motor Manufacturing, Derby
ESH supplied, installed and tested a trace heating system to perform the duty of temperature maintaining internal metal pipework at +30°C. This was achieved utilising type FBTBOJ20/2 self regulating heating tape.
Friday, 28 November 2014
Frankley WTW
Seven Trent Water's Frankley Water Treatment Works at Frankley, Birmingham, supplies drinking water to Birmingham and the surrounding areas. Part of the £31.5m project to upgrade Frankley WTW, ESH supplied and installed a total of 1270m of trace heating cable to perform the following duties:
- Provide frost protection to the water / lime pipework
- Temperature maintain the sodium bisulphite pipework at +15°C in a minimum ambient temperature of -20°C
Our FBTBOJ10/2 heating tapes were installed to the underside of the pipework in a straight trace configuration and secured to the plastic pipe using type FTA fixing tape.
Friday, 21 November 2014
Magnesium Elektron, Manchester
Our second visit to Magnesium Elektron saw ESH supply and install two runs of 40w/m trace heating circuits above hoppers, in order to temperature maintain them at +55°C.
Wednesday, 19 November 2014
Camfil APC, Hetwood
ESH supplied and installed type VCBOJ constant wattage heating tape to a large hopper and to the sides of it's cone. It was essential that the hopper was maintained at the elevated temperature to prevent plugging and corrosion.
Friday, 14 November 2014
Rhodia CLB Plant, Oldbury
Supplied and installed trace heating to provide temperature maintenance to a short run of caustic soda pipework. The requirement was to maintain +20°C in a minimum ambient temperature of -20°C.
Monday, 3 November 2014
Flint Ink UK, Wolverhampton

For this local project we supplied and installed trace heating to provide temperature maintenance on a large cylindrical tank. The steel tank, 2m diameter and 8.4m long, required maintaining at +70°C. Our design utilised type SC constant wattage heating tape controlled by DTC temperature control units.
Thursday, 30 October 2014
Magnesium Elektron, Manchester
Within this manufacturing plant, ESH designed, supplied and installed a trace heating system for three hopper cones. The system was designed to temperature maintain the hopper cones at +55°C in a minimum ambient temperature of -20°C. Type VC constant wattage heating cable was used and controlled by three DTC digital thermostats.
Monday, 6 October 2014
Robert Sanderson & Sons, Hull
Here ESH were contracted to design, supply and install trace heating to temperature maintain three large storage tanks, two tanks at +30°C and one at +10°C, all within a minimum ambient temperature of -20°C.
A total of 420m of Type FBT self regulating heating tape was required to complete the tank heating systems.
A total of 420m of Type FBT self regulating heating tape was required to complete the tank heating systems.
Tuesday, 19 August 2014
Rhodia UK, Oldbury
Within a potentially explosive atmosphere, ESH designed, supplied and installed an ATEX Approved 240v trace heating system to temperature maintain +90°C on flexible pipework.
Wednesday, 13 August 2014
Kingsdown Crematorium, Swindon
ESH designed, supplied and installed a trace heating system to temperature maintain a hopper at +100°C. Mineral insulated heating tape was fixed to the body of the hopper in order to achieve the desired temperature.
Tuesday, 8 July 2014
Samuel Smith Old Brewery
Monday, 23 June 2014
Kings Cross Station, London
ESH are very proud to have been involved in the £400m restoration and redevelopment of Kings Cross Station. We were contracted to design, supply and install a number of different trace heating systems throughout this iconic building:- Temperature maintenance of the HSWF pipework on the lower ground floor & basement cycle shower area,1050m of H2OWAT heating tape.
- Frost protection to the external roof BCWS pipework, 660m of FBT self regulating heating tape.
- Temperature maintenance of the BHWS pipework in Camden Library, 28m of H2OWAT heating tape.
- Freeze protection to the sprinkler pipework within the basement, 200m of VC constant wattage heating tape.
- Temperature maintenance of the domestic hot water supplies, tea point pipework on each floor, 200m of H2OWAT heating tape.
Friday, 13 June 2014
Solvay Ltd, Oldbury
For this international chemical group, ESH supplied and installed 240 volt trace heating cable for the temperature maintenance of stainless steel pipework containing formaldehyde, part of the system originally installed by ESH. Type VCBOJ constant wattage heating cable was used to meet the temperature requirements.
Monday, 9 June 2014
Amtico International Head Office, Coventry
Here ESH supplied and installed at trace heating system to stainless steel pipework containing Placticiser to maintain the temperature at +25°C. In total there was 20m of external and 190m of internal flow and return pipework which required heat tracing.
Thursday, 15 May 2014
The Brockmoor Foundry Ltd - Brierley Hill
Supplied and installed trace heating to provide temperature maintenance of a duct associated with a Schenk Sand Cooler. The duct was of steel construction measuring approximately 3.5m x 600mm diameter and needed to be maintained at a temperature of +60°C to +70°C.
Friday, 21 March 2014
Waste Disposal Plant, Swindon
ESH supplied and installed over 250 metres of type VC constant wattage heating tape in order to temperature maintain a large hooper, filter, feeds and valve at +70°C.
Tuesday, 4 February 2014
Haxby & Strensall WWTW
Within this waste water treatment works, ESH designed, supplied and installed a temperature maintenance trace heating system. The system was designed using type FBT self regulating heating tape in order to maintain the required temperature of +10°C on the plastic pipework.
Tuesday, 28 January 2014
Bourne Vale Pumping Station
ESH were contracted to supply materials and labour to install and commission a trace heating system for metal pipework containing caustic soda to be maintained at +20°C. The system was designed using type FBT self regulating heating cable.
Friday, 24 January 2014
Veolia Environmental, Tysley
ESH were contacted to design, supply and install a high temperature trace heating system to provide temperature maintenance of +110°C to a steel fly ash hopper (2m tall x 2.3m square).