Monday, 8 December 2014

New Primark Store, Northampton

ESH were contracted to supply and install a frost protection trace heating system to the external chilled water pipework on the roof, mezzanine area and service yard. The system was designed using type VCBOJ constant wattage heating tape.

Tuesday, 2 December 2014

Salford Royal Hospital

Supplied and installed type VCBOJ8/2 constant wattage trace heating tape to provide frost protection to external chilled water pipework. The heating tape was straight traced underneath the pipework and temperature controlled using our type STCI thermostats. 

Wednesday, 19 November 2014

Camfil APC, Hetwood

ESH supplied and installed type VCBOJ constant wattage heating tape to a large hopper and to the sides of it's cone. It was essential that the hopper was maintained at the elevated temperature to prevent plugging and corrosion.

Monday, 3 November 2014

Flint Ink UK, Wolverhampton


For this local project we supplied and installed trace heating to provide temperature maintenance on a large cylindrical tank. The steel tank, 2m diameter and 8.4m long, required maintaining at +70°C. Our design utilised type SC constant wattage heating tape controlled by DTC temperature control units.

Thursday, 30 October 2014

Magnesium Elektron, Manchester

Within this manufacturing plant, ESH designed, supplied and installed a trace heating system for three hopper cones. The system was designed to temperature maintain the hopper cones at +55°C in a minimum ambient temperature of -20°C. Type VC constant wattage heating cable was used and controlled by three DTC digital thermostats.

Monday, 27 October 2014

Jobling Purser Asphalt Plant, Newcastle-Upon-Tyne

As a highway maintenance specialists, Jobling Purser develop and manufacture a wide range of products used around the world. ESH designed, supplied and installed a trace heating system to maintain a 4" steel bitumen line at +80°C. 

In a minimum ambient temperature of -20°C, over 300 metres of type SC constant wattage heating tape was triple traced to the underside of the pipework in order to maintain the required product temperature.

Tuesday, 14 October 2014

New Marks & Spencer Store, Stoke On Trent

ESH Trace Heating Ltd supplied and installed a frost protection heating system to the MWS, BCWS, HWS and LTHW pipework. Within this brand new retail outlet, over 200 metres of type VCBOJ constant wattage heating tape was required.

Monday, 29 September 2014

Shoreham Technical Centre


At this design, development and research centre of internal combustion engines and systems, ESH designed, supplied and installed a trace heating system to heat raise pipework, prior to gas being carried, from a minimum ambient temperature of +18°C up to +47°C. The system was designed using type SC constant wattage heating tape.

Friday, 25 July 2014

Ercall Wood Academy, Telford


Ercall Wood will be the third new Academy, when it opens in September 2015, in Telford & Wrekin Council's £200m Building Schools for the Future project. Here at this local school, ESH were contracted to design, supply and install a frost protection trace heating system to the LTHW copper pipework on the academy's roof. The system utilised ESH's type VC constant wattage heating tape.

Thursday, 10 July 2014

Jobling Purser, Newcastle-Upton-Tyne

ESH supplied and installed a high temperature trace heating system to temperature maintain the Bitumen tank line pipework at +145ยบC. Type SC constant wattage heating tape was straight traced five times along the pipework length to achieve this high temperature. 

Tuesday, 8 July 2014

Samuel Smith Old Brewery


Within Yorkshire's oldest brewery, ESH supplied and installed a trace heating system to provide temperature maintenance to over 230m of stainless steel pipework. The required temperature was +25°C and this was achieved by installing our type VC constant wattage heating cable. 

Monday, 23 June 2014

Kings Cross Station, London

ESH are very proud to have been involved in the £400m restoration and redevelopment of Kings Cross Station. We were contracted to design, supply and install a number of different trace heating systems throughout this iconic building:
  • Temperature maintenance of the HSWF pipework on the lower ground floor & basement cycle shower area,1050m of H2OWAT heating tape.
  • Frost protection to the external roof BCWS pipework, 660m of FBT self regulating heating tape.
  • Temperature maintenance of the BHWS pipework in Camden Library, 28m of H2OWAT heating tape.
  • Freeze protection to the sprinkler pipework within the basement, 200m of VC constant wattage heating tape.
  • Temperature maintenance of the domestic hot water supplies, tea point pipework on each floor, 200m of H2OWAT heating tape.

Friday, 13 June 2014

Solvay Ltd, Oldbury

For this international chemical group, ESH supplied and installed 240 volt trace heating cable for the temperature maintenance of stainless steel pipework containing formaldehyde, part of the system originally installed by ESH. Type VCBOJ constant wattage heating cable was used to meet the temperature requirements.

Wednesday, 28 May 2014

St Mary's Catholic College, Blackpool

With over 1800 pupils, St Mary's is the largest Roman Catholic secondary school in Lancashire. Here ESH designed, supplied and installed a frost protection trace heating system for the schools internal sprinkler pipework. The pipework was double traced with a total of 460m of type WTB constant wattage heating cable and monitored using ESH TracePro monitoring units.

Thursday, 3 April 2014

City Hospital, Nottingham


Within City Hospitals new £6.6m cystic fibrosis unit, ESH were contracted to design, supply and install a trace heating system to provide frost protection to the external MCWS and HWS pipework. The system was designed using type VCBOJ constant wattage heating cable.

Tuesday, 1 April 2014

Doncaster Royal Infirmary

ESH designed, supplied and installed a type VC constant wattage trace heating system in order to frost protect the hospitals low temperature hot water (LTHW) pipework.

Thursday, 13 February 2014

Marriot Court, Bishop Storford


For this new office development ESH were asked to design and supply underfloor ramp heating to two separate sloped areas on the car park. In total 390m of type VC constant wattage was supplied along with 4 ETO thermostats and ancillaries.