Showing posts with label High Temperature Trace Heating. Show all posts
Showing posts with label High Temperature Trace Heating. Show all posts

Tuesday, 16 December 2014

Wilton Centre, Redcar


The Wilton Centre provides office, laboratory and pilot plant accommodation. Here ESH were contracted to design, supply and install a high temperature trace heating system to maintain pipework between +100ºC and +180ºC within a Zone I, Gas Group 11b, Classification T3, hazardous area.

Thursday, 4 December 2014

Veolia Environmental, Tysley

Supplied and installed trace heating to provide temperature maintenance of +110°C to a fly ash hopper. The steel hopper, 2m tall and 2.3m square, was installed with mineral insulated heating cable in order to achieve the required temperatures.

Tuesday, 19 August 2014

Rhodia UK, Oldbury

Within a potentially explosive atmosphere, ESH designed, supplied and installed an ATEX Approved 240v trace heating system to temperature maintain +90°C on flexible pipework.

Thursday, 10 July 2014

Jobling Purser, Newcastle-Upton-Tyne

ESH supplied and installed a high temperature trace heating system to temperature maintain the Bitumen tank line pipework at +145ºC. Type SC constant wattage heating tape was straight traced five times along the pipework length to achieve this high temperature. 

Friday, 4 July 2014

Wilton Centre, Redcar

Our second large project here at the Wilton Centre saw ESH supply materials and labour to extend the existing trace heating circuits, relocate existing thermostats and install new circuits. The high temperature trace heating system needed to maintain the pipework temperature at +150°C all within a Zone 1 Gas Group llb, T3 Classification hazardous area.

Friday, 24 January 2014

Veolia Environmental, Tysley

ESH were contacted to design, supply and install a high temperature trace heating system to provide temperature maintenance of +110°C to a steel fly ash hopper (2m tall x 2.3m square).